- Operating Temperature:
-
- Voltage - Rated:
-
- Size / Dimension:
-
- Termination:
-
- Ingress Protection:
-
- Approvals:
-
- Width:
-
- Air Flow:
-
- Static Pressure:
-
- Noise:
-
- Ausgewählte Bedingungen:
Entdecken Sie 16 -Produkte
Bild | Teilenummer | Hersteller | Menge | Lieferfrist | Stückpreis | Kaufen | Beschreibung | Series | Operating Temperature | Voltage - Rated | Features | Size / Dimension | Termination | Ingress Protection | Approvals | Width | Air Flow | Static Pressure | Fan Type | Noise | RPM | Weight | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Bild | Teilenummer | Hersteller | Menge | Lieferfrist | Stückpreis | Kaufen | Beschreibung | Series | Operating Temperature | Voltage - Rated | Features | Size / Dimension | Termination | Ingress Protection | Approvals | Width | Air Flow | Static Pressure | Fan Type | Noise | RPM | Weight | ||
Orion Fans |
40
|
3 tage |
-
|
MOQ: 1 MPQ: 1
|
FAN AXIAL 225X80MM BALL 115VAC
|
OA225 | -40 ~ 140°F (-40 ~ 60°C) | 115VAC | - | Round - 225mm Dia | Terminal Block | IP55 - Dust Protected,Water Resistant | TUV | 80.00mm | 600.0 CFM (16.80m3/min) | 0.670 in H2O (166.9 Pa) | Tubeaxial | 61.0 dB | 2800 RPM | - | ||||
Mechatronics Fan Group |
67
|
3 tage |
-
|
MOQ: 1 MPQ: 1
|
FAN AXIAL 180X90MM 115VAC
|
UF18JC-4 | - | 115VAC | - | Square - 180mm L x 180mm H | 2 Terminals | - | - | 90.00mm | 460.0 CFM (12.88m3/min) | 1.060 in H2O (264.0 Pa) | Tubeaxial | 59.0 dB(A) | 3400 RPM | 4.8 lbs (2.2kg) | ||||
Orion Fans |
6
|
3 tage |
-
|
MOQ: 1 MPQ: 1
|
FAN AXIAL 320X141.5MM 115VAC
|
OA225 | -40 ~ 176°F (-40 ~ 80°C) | 115VAC | Kit | Square - 320mm L x 320mm H | Terminal Block | IP55 - Dust Protected,Water Resistant | - | 141.5mm | 600.0 CFM (16.80m3/min) | 0.550 in H2O (137.0 Pa) | Tubeaxial | 59.0 dB(A) | 2800 RPM | - | ||||
Mechatronics Fan Group |
8
|
3 tage |
-
|
MOQ: 1 MPQ: 1
|
IMPELLER 190X70MM 230VAC
|
UF190A | -40 ~ 122°F (-40 ~ 50°C) | 230VAC | - | Round - 190mm Dia | 2 Wire Leads | - | - | 70.00mm | 370.0 CFM (10.36m3/min) | 1.200 in H2O (298.9 Pa) | Motorized Impellers | 63.0 dB(A) | 2700 RPM | 2.7 lbs (1.2kg) | ||||
Mechatronics Fan Group |
10
|
3 tage |
-
|
MOQ: 1 MPQ: 1
|
IMPELLER 190X70MM 230VAC RING
|
UF190A | -40 ~ 122°F (-40 ~ 50°C) | 230VAC | - | Round - 235mm Dia | 2 Wire Leads | - | - | 87.20mm | 247.0 CFM (6.92m3/min) | 1.500 in H2O (373.6 Pa) | Motorized Impellers | 63.0 dB(A) | 2700 RPM | 3.2 lbs (1.5kg) | ||||
Orion Fans |
2
|
3 tage |
-
|
MOQ: 1 MPQ: 1
|
FAN TUBEAXIAL 317X317MM 115VAC
|
OA225LFGS | 104 ~ 158°F (40 ~ 70°C) | 115VAC | Kit | Square - 317mm L x 317mm H | Terminal Block | IP55 - Dust Protected,Water Resistant | cURus,TUV | 125.5mm | 600.0 CFM (16.80m3/min) | 0.550 in H2O (137.0 Pa) | Tubeaxial | 59.0 dB | 2800 RPM | - | ||||
Orion Fans |
2
|
3 tage |
-
|
MOQ: 1 MPQ: 1
|
FAN AXIAL 322.7X322.7MM 115VAC
|
OA225LFGH | 104 ~ 158°F (40 ~ 70°C) | 115VAC | Kit | Square - 322.7mm L x 322.7mm H | Terminal Block | IP55 - Dust Protected,Water Resistant | cURus,TUV | 133.4mm | 600.0 CFM (16.80m3/min) | 0.550 in H2O (137.0 Pa) | Tubeaxial | 59.0 dB | 2800 RPM | - | ||||
Orion Fans |
Anfrage
|
- |
-
|
MOQ: 1 MPQ: 1
|
FAN IMP MTRZD 190X70 230V W/CAP
|
OAB190 | -40 ~ 140°F (-40 ~ 60°C) | 230VAC | - | Round - 190mm Dia | 2 Wire Leads | - | - | 70.00mm | 370.0 CFM (10.36m3/min) | 1.200 in H2O (298.9 Pa) | Motorized Impellers | 63.0 dB | 2700 RPM | - | ||||
Mechatronics Fan Group |
Anfrage
|
- |
-
|
MOQ: 1 MPQ: 1
|
FAN AXIAL 180X90MM 115VAC TERM
|
UF18JC-4 | - | 230VAC | - | Square - 180mm L x 180mm H | 2 Terminals | - | - | 90.00mm | 460.0 CFM (12.88m3/min) | 1.060 in H2O (264.0 Pa) | Tubeaxial | 59.0 dB(A) | 3400 RPM | 4.8 lbs (2.2kg) | ||||
Mechatronics Fan Group |
Anfrage
|
- |
-
|
MOQ: 1 MPQ: 1
|
FAN AXIAL 180X90MM 115VAC WIRE
|
UF18JC-4 | - | 115VAC | - | Square - 180mm L x 180mm H | 2 Wire Leads | - | - | 90.00mm | 460.0 CFM (12.88m3/min) | 1.060 in H2O (264.0 Pa) | Tubeaxial | 59.0 dB(A) | 3400 RPM | 4.8 lbs (2.2kg) | ||||
Mechatronics Fan Group |
Anfrage
|
- |
-
|
MOQ: 1 MPQ: 1
|
FAN AXIAL 180X90MM 230VAC WIRE
|
UF18JC-4 | - | 230VAC | - | Square - 180mm L x 180mm H | 2 Wire Leads | - | - | 90.00mm | 460.0 CFM (12.88m3/min) | 1.060 in H2O (264.0 Pa) | Tubeaxial | 59.0 dB(A) | 3400 RPM | 4.8 lbs (2.2kg) | ||||
Sunon Fans |
Anfrage
|
- |
-
|
MOQ: 1 MPQ: 1
|
FAN AXIAL 254X89MM 115VAC TERM
|
A | - | 115VAC | - | Round - 254mm Dia | 2 Terminals | - | CE,CUR,TUV,UL | 89.00mm | 585.0 CFM (16.38m3/min) | 0.310 in H2O (77.2 Pa) | Tubeaxial | 60.0 dB(A) | 1900 RPM | 5 lbs (2.3kg) | ||||
ebm-papst Inc. |
Anfrage
|
- |
-
|
MOQ: 1 MPQ: 1
|
FAN BLOWER CF 380X170MM 230VAC
|
QR08 | - | 230VAC | - | Rectangular - 502mm L x 140mm H (92mm Dia) | Terminal Block | - | - | 170.0mm | 456.0 CFM (12.77m3/min) | - | Blower,Cross Flow | 70.0 dB(A) | - | 10 lbs (4.5kg) | ||||
ebm-papst Inc. |
Anfrage
|
- |
-
|
MOQ: 1 MPQ: 1
|
FAN BLOWER CF 380X170MM 230VAC
|
QR08 | - | 230VAC | - | Rectangular - 502mm L x 140mm H (92mm Dia) | Terminal Block | - | - | 170.0mm | 456.0 CFM (12.77m3/min) | - | Blower,Cross Flow | 70.0 dB(A) | - | 10 lbs (4.5kg) | ||||
Sunon Fans |
Anfrage
|
- |
-
|
MOQ: 1 MPQ: 1
|
FAN AXIAL 254X89MM 115VAC WIRE
|
A | - | 115VAC | - | Round - 254mm Dia | 2 Wire Leads | - | CE,CUR,TUV,UL | 89.00mm | 585.0 CFM (16.38m3/min) | 0.310 in H2O (77.2 Pa) | Tubeaxial | 60.0 dB(A) | 1900 RPM | 5 lbs (2.3kg) | ||||
Sunon Fans |
Anfrage
|
- |
-
|
MOQ: 1 MPQ: 1
|
FAN AXIAL 254X89MM 115VAC TERM
|
A | 14 ~ 176°F (-10 ~ 80°C) | 115VAC | - | Round - 254mm Dia | 2 Terminals | - | - | 89.00mm | 585.0 CFM (16.38m3/min) | 0.310 in H2O (77.2 Pa) | Tubeaxial | 60.0 dB(A) | 1900 RPM | 5.1 lbs (2.3kg) |